Connectors shall be processed in such a manner as to be uniform in quality and shall be free. Salt spray corrosion eia36426, condition b meets mateability and contact resistance requirements fluid immersion mildtl835 meets mateability requirements humidity eia36431 meets d. November 20, 2008 ei a standard tp31c humi di ty test procedure for electri cal connectors and sockets revision of ei a36431b ei a36431c e i a 3 6 4 3 1 c november 2008 ei a standards electronic components association notice eia engineering standards and publications are designed to serve the public interest. Size milliohms 16 5 20 9 22 15 24 20 26 31 28 50 eia36423. Configuration management terminology for use with any product line. Solderability of contact terminations test procedure for electrical connectors eia36452 revision b superseded see the following. Eia 364 92 2008 tp92 wire bending test procedure for insulation displacement contacts idc for electrical connectors eia 364 96 2002 eia 364 1002 2008 test methodology for assessing the performance of complaint contact terminations used as free standing contacts or in electrical connectors and sockets. C2014 tp26c salt spray test procedure for electrical connectors, contacts and sockets from sai global. Eia36410 altitude immersion no evidence of moisture on connector interface or contacts. The eia ceased operations on february 11, 2011, but the former sectors continue to serve the constituencies of eia.

Milprf39012e 27 april 2005 superseding milprf39012d july 1995 performance specification connectors, coaxial, radio frequency, general specification for this specification is approved for use by all departments and agencies of the department of defense. Series 28 hiperd introduction and technical reference. Salt spray corrosion test procedure for electrical connectors, contact and sockets eia36426 revision c current see the following. Eia36426 pdf, eia36426 description, eia36426 datasheets. Eia36420 withstanding voltage test procedure for electrical connectors, sockets and coaxial contacts eia36421 insulation resistance test procedures for electrical connectors. Box c700, 100 barr harbor drive, west conshohocken, pa 194282959. Size pounds newtons 8 25 111 22 9 40 20 9 40 eia 364 29. Dust test ip68, iec60529 20mbars air pressure, 8 hours. Shell material, finish code eia36426 test condition duration hours aluminum, cadmium plating 01 a 96 48 for m835 aluminum, electroless nickel plating 02 b 48. Housing 26 resin material x pa66 0 plating x matte tin 1 gold flash 2 15in. Eiaeca36426 salt spray test procedure for electrical connectors, contacts and sockets eia36427. Eia36428 datasheet1041 pages itt connectors, electric.

Here is a list of electronic industries alliance eia standards the eia ceased operations on february 11, 2011, but the former sectors continue to serve the constituencies of eia. Here is a list of electronic industries alliance eia standards. Eia36437 contact engagement and separation test procedure for electrical connectors. The contact retaining system shall be free of foreignmaterial, adhesive, or any obstruction that would prevent smooth contact insertion and positive retention. They were placed on your computer when you launched this website. This standard sets up testing methods for determining the effects of a saltladen atmosphere on electrical connector. Cross reference of eia 364 procedures and mil std 44. Eia 36438b condition b apply force at a rate of 89 n per minute to 333 n and hold for 1 hour. Amp test specifications vs eia and iec test methods. May 2, 2008 eia standard tp38ceia36438c cable pullout test procedure for electrical connectors eia36438c revision of eia36438b may 2008 eia standards electronic components association. Eia 364 21 insulation resistance test procedure for electrical connectors, sockets, and coaxial contacts eia 364 23 low level contact resistance test procedure for electrical connectors and sockets eia 364 26 salt spray test procedure for electrical connectors, contacts and sockets eia 364 27 mechanical shock specified pulse test. Test methods are numbered within the eia 364 series of documents.

Eia 36428 archives document centers standards forum. Eia36421 insulation resistance test procedure for electrical connectors, sockets, and coaxial contacts superseded by eiaeca36421. International organizations for standards iso iso100121 equipment, quality assurance requirements for measuring, part 1. Inserts shall be molded or bonded with a bondbarrier between all adjacent contacts and outside edge and of onepiece construction, except for idc. Eia 364 26 datasheet, eia 364 26 datasheets, eia 364 26 pdf, eia 364 26 circuit. It replaces the previous eia36428e dated 82006 eia 36428 is one of a series of approximately 110 subparts of eia 364 devoted to various test procedures for connectors and originally released by eia. If any shipment is found to be defective we will accept r eturn for repair or replace. Development began in 1994, with the electronic industries alliance s eia g33 committee on data and configuration management initiated a task to develop an industry configuration management standard. The contact datasheet search, datasheets, datasheet search site for electronic components and semiconductors, integrated circuits, diodes and other semiconductors. Eia 364 10 altitude immersion no evidence of moisture on connector interface or contacts. In addition, connectors shall meet contact resistane, lw circuit level contact resistance and mating force requirements. Tp26c salt spray test procedure for electrical connectors, contacts and sockets.

Hyperboloid contacts 140 58th street 8e, brooklyn, ny 11220 ph. Eia36426 datasheet, eia36426 datasheets, eia36426 pdf, eia36426 circuit. Low level signal level, hours eia 364 26 condition b shock 50 gs mildtl835, milstd44a method 2004. Environmental performance of electrical connectors. Normal force test procedure for electric connectors this document comes with our free notification service, good for the life of the document.

The contact retaining system shall be free of foreign. May 2, 2008 eia standard tp38ceia 364 38c cable pullout test procedure for electrical connectors eia 364 38c revision of eia 364 38b may 2008 eia standards electronic components association. Superseded by eiaeca36421 to find similar documents by federal supply class code. Salt spray corrosion eia 364 26, condition b meets mateability and contact resistance requirements fluid immersion mildtl835 meets mateability requirements humidity eia 364 31 meets d. Eiaeca 36426 datasheet, eiaeca 36426 datasheets, eiaeca 36426 pdf, eiaeca 36426 circuit. Salt spray test procedure for electrical connectors, contacts and. Find the most uptodate version of eia364 at engineering360. Rjack industrial rj45 solution optical cable corporation. Electrical connectorsocket test procedures including environmental classifications. Eia 36428f, titled tp 28f, vibration test procedure for electrical connectors and sockets, has just been released. The database currently tracks more than 200 crude oil, hgl, and finished petroleum products pipeline projects. Mated connectors shall be tested in accordance with eia36431, test condition a, method ii. Connectors shall be processed in such a manner as to be uniform in quality and shall be. Water submersion, ip68,iec60529 1m depth, 48 hours.

Energy information administration eia has released the first iteration of its u. Insulation may degrade if the connector is exposed to repeated dwv tests and the dwv test voltage. Inserts shall be designed with suitable sections and radii such that they willnot readily chip, crack, or break in assembly or in normal service. Eiaeca36426 pdf, eiaeca36426 description, eiaeca364. Eia36432 thermal shock temperature cycling test procedure for electrical connectors and sockets. Fsc 5935 connectors, electrical this document comes with our free notification service, good for the life of the document. Astm a582a582m free machining stainless and heat resisting steel bars. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia 364 31 datasheet, eia 364 31 circuit. Find the most uptodate version of eia36426 at engineering360. Mildtl55302g 9 november 2009 superseding mildtl55302f march 2003. Low level signal level, hours eia36426 condition b shock 50 gs mildtl835, milstd44a method 2004. Our policy towards the use of cookies techstreet, a clarivate analytics brand, uses cookies to improve your online experience.

Connectors shall be uniform in quality and shall be free from burrs, scratches, cracks, voids, chips. Eia36426 datasheet1441 pages itt connectors, electric. Eia36420 and milstd44 both dictate that the dielectric withstanding voltage dwv be established as 75% of the minimum breakdown voltage of the connector breakdown voltage is defined as the voltage at which a connector failure is observed. This standard establishes a method to determine the effectiveness of round jacketed cable to connector strain relief seal, or flat cable to connector strain relief seal or interface to withstand strain under repeated alternating cableflexing stresses as experienced in use with molded or mechanical backshell cable strainrelief designs commonly used with electrical connectors. Itt detail specification,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. Itt connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. Eia 364 38b condition b apply force at a rate of 89 n per minute to 333 n and hold for 1 hour. Ieh warrants its products to be free of defects affecting normal use. This standard sets up testing methods for determining the effects of a saltladen atmosphere on electrical connector components, finishes and mechanisms. Connectors shall be uniform in quality and shall be free from burrs, scratches, cracks, voids, chips, blisters. Connector shall meet dielectric withstanding voltage.

Dielectric strength mateunmate connectors, apply 100v ac for 1 minute at sea level. Insulation resistance mateunmate connectors, apply 100v dc for 1 minute at sea level between adjacent terminal or ground. Itt connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs. Electrical connectorsocket test procedures including environmental. Electronic industries association eia eia557 statistical process control systems. Size pounds newtons 8 25 111 22 9 40 20 9 40 eia36429. Cross reference of eia 364 procedures and mil std 44 methods. Eia36426 salt spray test procedure for electrical connectors, contacts and sockets eia36427 mechanical shock specified pulse test procedure for electrical connectors. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia 364 29 datasheet, eia 364 29 circuit. New eia 36428 revision f just released on vibration test. Vibration, 4 hours per axis, eia36428 test condition iv, 12 hours total.